Mason jack up floor slab system we believe that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
Mason fsn floating floor.
Housing suffix indicates housing height i e.
Fsn4 indicates 4 100mm floor and housing.
We believe that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
Fsn6 6 150mm floor and housing etc.
Fsn jack up floating floor isolation mounts it has been proven that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
Fs spring jack up floating floor gymnasiums.
The isolators can be either rubber or spring depending on the nature of the noise or vibration.
0 500 1000.
Castings can be modified for floors over 6 150mm thick.
Air gap a floor thickness b.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concret.
This uses the mason jack up system to raise a concrete layer.
Fsn 3 4 5 6 25 0 3500 12 47 12147 red white 50 60 1675 2350 3500 761 1068 1590 black gray fsn housing height matches floor thickness.
Housing suffix indicates housing height i e.
Fsn rubber concrete jack up system.
Rubber floating floor applications.
There are thee main varieties of concrete floating floor.
The design and type of the floating floor is determined by the level of required isolation the supporting structure and any loads on the floor from walls equipment etc.
A floor supported by mason low dynamic stiffness rubber the time tested low frequency exposure proof and truly structural material at lower cost.
Fsn4 indicates a 4 floor and housing.
The fsn system ensures there is no bridging of the two elements due to slurry ingress plastic sheeting is placed on the sub floor as a breaker layer.
Our riverbank test data demonstrates that a four inch thick concrete floor floating on neoprene mounts improves the stc by 25 if raised two inches and that the inr goes up by 44.
Fsn6 a 6 floor and housing etc.
Castings can be modified for floors over 6 thick.
Fsn data sheet ds 50 4 floating floor lds jack up mountings type fsn ratings 1336 housing fsn housing height matches floor thickness.
Have long experience in this field and would be happy to help interpret any requirements or specifications and provide a practical.
There are a variety of floating floor systems available.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concrete floor is poured.
Situations arise where there is a requirement for a lower natural frequency in the floating floor element than what can be achieved by a rubber isolator.